 List of calibration parameters
Pr.
C2 (902)
Terminal 2 frequency setting bias frequency
C3 (902)
Terminal 2 frequency setting bias
125 (903)
Terminal 2 frequency setting gain frequency
C4 (903)
Terminal 2 frequency setting gain
C5 (904)
Terminal 4 frequency setting bias frequency
C6 (904)
Terminal 4 frequency setting bias
126 (905)
Terminal 4 frequency setting gain frequency
C7 (905)
Terminal 4 frequency setting gain
 Operation command
Instruction
Bit
Item
code
length
Operation
HFA
8 bits
command
Operation
command
HF9
16 bits
(extended)
*1
A function described in parentheses ( ) is initially assigned to the terminal. The function changes depending on the setting of Pr.180 to Pr.182
(Input terminal function selection)
*2
During RS-485 communication through the PU connector, only the Forward rotation command and Reverse rotation command signals can be
used.
 Inverter status monitor
Instruction
Item
code
length
Inverter
status
H7A
8 bits
monitor
Inverter
status
H79
16 bits
monitor
(extended)
*1
A function described in parentheses ( ) is initially assigned to the terminal. The function changes depending on the setting of Pr.190 to Pr.195
(Output terminal function selection).
Name
*1
Description
b0: AU (Terminal 4 input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (Low-speed operation command)
b4: RM (Middle-speed operation command)
b5: RH (High-speed operation command)
b6: Second function selection
b7: Output stop
b0: AU (Terminal 4 input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (Low-speed operation command)
b4: RM (Middle-speed operation command)
b5: RH (High-speed operation command)
b6: Second function selection
b7: Output stop
b8 to b15: –
(page
142).
Bit
*1
Description
b0: NET Y0 to Y4
b1: NET Y0 to Y4
b2: NET Y0 to Y4
b3: NET Y0 to Y4
b4: NET Y0 to Y4
b5: –
b6: FU (Output frequency detection)
b7: ABC (Fault)
b0: NET Y0 to Y4
b1: NET Y0 to Y4
b2: NET Y0 to Y4
b3: NET Y0 to Y4
b4: NET Y0 to Y4
b5: –
b6: Output frequency detection
b7: ABC (Fault)
b8 to b14: –
b15: Fault occurrence
Instruction code
Read
Write
Extended
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
[Example 1] H0002 Forward rotation
b15
0
0
0
0
[Example 2] H0804 Low-speed reverse operation
(When Pr. 182 RH terminal function selection is set to "0")
b15
0
0
0
0
[Example 1] H02
b7
0
[Example 2] H00
b7
0
[Example 1] H0002 During forward rotation
b15
0
0
0
0
[Example 2] H8080 Stop at fault occurrence
b15
1
0
0
0
5.11 (N) Communication operation parameters
Example
[Example 1] H02 Forward rotation
b7
b0
0
0
0
0
0
0
1
0
[Example 2] H00 Stop
b7
b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
Example
During forward
rotation
b0
0
0
0
0
0
1
0
Stop at fault
occurrence
b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
5. PARAMETERS
2
2
3
4
5
6
7
8
b0
0
1
0
9
b0
1
0
0
10
b0
0
1
0
b0
0
0
0