Pr.
Pr.
group
Amplitude compensation
A302
594
amount during deceleration
Amplitude compensation
A303
595
amount during acceleration
A304
596
Amplitude acceleration time
A305
597
Amplitude deceleration time
A601
131
PID upper limit
A602
132
PID lower limit
A610
128
PID action selection
A611
133
PID action set point
PID control automatic
A612
127
switchover frequency
A613
129
PID proportional band
A614
130
PID integral time
A615
134
PID differential time
Output interruption detection
A621
575
time
Output interruption detection
A622
576
level
Output interruption cancel
A623
577
level
A680
573
4 mA input check selection
A702
57
Restart coasting time
A703
58
Restart cushion time
Stall prevention operation
A710
165
level for restart
A730
261
Power failure stop selection
 N: Communication operation
parameters
Parameters for the setting of communication operation such
as the communication specifications or operating
characteristics.
Pr.
Pr.
group
N000
549
Protocol selection
Communication EEPROM
N001
342
write selection
Stop mode selection at
N013
502
communication error
PU communication station
N020
117
number
N021
118
PU communication speed
N022
119
PU communication data length
PU communication stop bit
N023
119
length
PU communication parity
N024
120
check
N025
121
PU communication retry count
PU communication check time
N026
122
interval
PU communication waiting
N027
123
time setting
Refer to
Name
page
151
151
151
151
152
152
152
152
152
152
152
152
152
152
152
139
159
159
159
160
Refer
Name
to page
165
165
165
168
168
168
168
168
168
168
168
Pr.
Pr.
group
PU communication CR/LF
N028
124
selection
N080
343
Communication error count
 G: Control parameters
Parameters for motor control.
Pr.
Pr.
group
G000
0
Torque boost
G001
3
Base frequency
G002
19
Base frequency voltage
Energy saving control
G030
60
selection
G040
100
V/F1 (first frequency)
G041
101
V/F1 (first frequency voltage)
G042
102
V/F2 (second frequency)
V/F2 (second frequency
G043
103
voltage)
G044
104
V/F3 (third frequency)
G045
105
V/F3 (third frequency voltage)
DC injection brake operation
G100
10
frequency
DC injection brake operation
G101
11
time
G106
250
Stop selection
DC injection brake operation
G110
12
voltage
Regeneration avoidance
G120
882
operation selection
Regeneration avoidance
G121
883
operation level
Regeneration avoidance
G123
885
compensation frequency limit
value
Regeneration avoidance
G124
886
voltage gain
Regeneration avoidance
G125
665
frequency gain
Increased magnetic excitation
G130
660
deceleration operation
selection
G131
661
Excitation increase rate
Increased magnetic excitation
G132
662
current level
G203
245
Rated slip
Slip compensation time
G204
246
constant
Constant-power range slip
G205
247
compensation selection
*1
The parameter number in parentheses is the one used
(displayed) on the LCD operation panel and the parameter
unit.
Refer
Name
to page
168
182
Refer
Name
to page
193
194
194
195
195
195
195
195
195
195
197
197
198
197
199
199
199
199
199
200
200
200
202
202
202
83
5. PARAMETERS
5.1 Parameter list
4
2
3
4
5
6
7
8
9
10

Hide quick links: