Peripheral Devices - Mitsubishi Electric FR-CS84-012 Instruction Manual

Freqrol-cs80
Hide thumbs Also See for FR-CS84-012:
Table of Contents

Advertisement

2.1.2

Peripheral devices

Check the model of the inverter you purchased. Appropriate peripheral devices must be selected according to the capacity.
Refer to the following table to prepare appropriate peripheral devices.
 Molded case circuit breaker / earth leakage circuit breaker
• This is a matrix showing the rated current of the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELB)
(NF or NV type) according to the selected inverter and rating.
Voltage
Inverter model
FR-CS84-012
FR-CS84-022
FR-CS84-036
Three-
FR-CS84-050
phase
FR-CS84-080
400 V
FR-CS84-120
class
FR-CS84-160
FR-CS84-230
FR-CS84-295
FR-CS82S-025
Single-
FR-CS82S-042
phase
200V
FR-CS82S-070
class
FR-CS82S-100
NOTE
• Select an MCCB according to the power supply capacity.
• Install one MCCB per inverter. For the use in the United States or Canada, provide the appropriate UL and cUL listed fuse that
is suitable for branch circuit protection. (Refer to the FREQROL-CS80 Instructions and Cautions for Use of Inverters.)
• When the inverter capacity is larger than the motor capacity, select an MCCB and a magnetic contactor according to the
inverter model, and select cables and reactors according to the motor output.
• When the breaker on the inverter's input side trips, check for the wiring fault (short circuit), damage to internal parts of the
inverter etc. The cause of the output shutoff must be identified and removed before turning ON the power of the breaker.
18
2. INSTALLATION AND WIRING
2.1 Peripheral devices
Without the power factor
improving reactor
5 A
5 A
10 A
15 A
20 A
30 A
30 A
50 A
60 A
10 A
15 A
30 A
40 A
MCCB
INV
M
MCCB
M
INV
With the power factor
improving reactor
5 A
5 A
10 A
10 A
15 A
20 A
30 A
40 A
50 A
5 A
10 A
15 A
30 A

Hide quick links: