A.14 CPU 214 AC Power Supply, AC Inputs, Relay Outputs
Model Number: 6ES7 214-1GC01-0XB0
General Features
Physical Size (L x W x D)
197 x 80 x 62 mm
(7.75 x 3.15 x 2.44 in.)
Weight
0.5 kg (1.0 lbs.)
Power Dissipation
9 W
User program size/storage
2K Words / EEPROM
User data size/storage
2K Words / RAM
Data and TOD Retention
Supercap
190 hr typ. (120 hr minimum
Optional Battery
200 days continuous usage
1
Local I/O
14 Inputs / 10 Outputs
Max. I/O Expansion Modules
7
Digital I/O Supported
64 Inputs / 64 Outputs
Analog I/O Supported
16 Inputs / 16 Outputs
0.8 µs/instruction
Boolean Execution Speed
Internal Memory Bits
256
Timers
128 Timers
Counters
128 Counters
High-speed counters
1 Software (2 KHz max.)
2 Hardware (7 KHz max. ea.)
TOD Clock Tolerance
6 minutes per month
Pulse Outputs
Not recommended
Analog Adjustments
2
Standards Compliance
UL 508
FM Class I, Division 2
VDE 0160 compliant
CE compliant
Input Points
Input Type (IEC 1131-2)
Type 1 Sinking
ON State Range
79 to 135 VAC, 47 to 63 Hz
4 mA minimum
ON State Nominal
120 VAC, 60 Hz. 7mA
OFF State Maximum
20 VAC, 1 mA
Maximum Response Time
0.2 ms to 8.7 ms selectable
plus 15.0 ms for fixed filter
15.2 ms default
Optical Isolation
1500 VAC, 1 minute
1
The CPU reserves 16 input and 16 output image register points for local I/O.
A-30
Output Points
Output Type
Voltage Range
Maximum Load Current
Overcurrent Surge
Isolation Resistance
Switching Delay
Lifetime
at 40 C)
Contact Resistance
Isolation
Coil to Contact
Contact to Contact
Short Circuit Protection
Power Supply
Voltage / Frequency Range
Input Current
Hold Up Time
Inrush Current
Fusing (non-replaceable)
5 VDC Current
Isolated
CSA C22.2 142
DC Sensor Supply
Voltage Range
Ripple/noise (<10Mhz)
24 VDC Available Current
Short Circuit Current Limit
Isolated
Relay, dry contact
5 to 30 VDC / 250 VAC
2 A/point
7 A with contacts closed
100 M minimum (new)
10 ms maximum
10,000,000 Mechanical
100,000 with Rated Load
200 m
maximum (new)
1500 VAC, 1 minute
1000 VAC, 1 minute
None
85 to 264 VAC at 47 to 63 Hz
4.5 VA typical, CPU only
50 VA max. load
20 ms min. from 110VAC
20 A peak at 264 VAC
2 A, 250 V, Slow Blow
340 mA for CPU
660 mA for expansion I/O
Yes. Transformer, 1500 VAC,
1 minute
20.4 to 28.8 VDC
1 V peak-to-peak maximum
280 mA
< 600 mA
No