Use Program 16-02 : Department Group Assignment for Extensions to set the Department
Program
Groups. The system uses these groups (32 Department Groups) for Department Calling. Assign pilot
numbers to Department Groups you set up in Program 11-07. This lets system users place calls to the
16
departments. Use Program 16-01 to set the priority of each extension in each Department Group.
When a call comes to the group, the extensions ring in order of their priority.
Input Data
Item
No.
01
The initial value of a priority becomes the ports numerical order assigned in Programs 11-02 and 11-04. (Ex-
tension ports are 1 ~ 128 (SL1000) 120 (SL1100) Virtual extension ports are 1 ~ 50.)
Conditions
None
Feature Cross Reference
• Department Calling
2-152
Downloaded from
www.Manualslib.com
Program 16 : Department Group Setup

16-02 : Department Group Assignment for Extensions

Extension Number
Group Num-
Priority
ber
1 ~ 32
1 ~ 999
manuals search engine
Maximum four digits (SL1000)
Maximum eight digits (SL1100)
Default
Description
1 - xxx
Set up the Department Group
(See Note)
called by the pilot number and
the extension priority when a
group is called. Call Pickup
Groups are set up in 23-02.