ISSUE 1.0
Level
IN
Description
Use Program 10-03 : ETU Setup to setup and confirm the Basic Configuration data for each unit.
When changing a defined terminal type, first set the type to 0 and then plug the new device in to have
the system automatically define it or you may have to reseat the unit.
The items highlighted in gray are read only and cannot be changed.
Input Data
For HBI PKG Setup (SL1100)
Item No.
01
02
03
04
05
06
For ESIU PKG Setup (SL1100)
Item No.
01
02
10
12
Programming Manual
Downloaded from
www.Manualslib.com
Program 10 : System Configuration Setup
Physical Port Number
Item
Terminal Type
Logical Port Number
Transmit Gain level for SLT
Receive Gain level for SLT
Select port type
Multi-Line Telephone Line
Physical Port Number
Item
Terminal Type (B1)
Logical Port Number
Bottom option information
Multi-Line Telephone Line
This program can only be change by
using PC Programming.
manuals search engine
10-03 : ETU Setup
01 ~ 08
Input Data
0 = No setting
1 = Multi-Line Telephone
2 = SLT
8 = Door Phone
10 = DSS Console
3 ~ 7, 9, 11, 12 = Not Used
1 ~ 128
1 ~ 63
(- 15.5 ~ + 15.5dB)
1 ~ 63
(- 15.5 ~ + 15.5dB)
0 = Hybrid Port
1 = Door Phone
0 = None
1 = 12 Line
2 = 24 Line
01 ~ 08
Input Data
0 = No setting
1 = Multi-Line Telephone
10 = DSS Console
0 = No setting
1 = Multi-Line Telephone (1 ~ 72)
10 = DSS Console (1 ~ 12)
0 = None
4 = WHA
0 = None
12 = 12 Line
24 = 24 Line
SL1000/SL1100
Program
10
Default
2
32
32
0
Default
0
0
0
0
2-5