SL1000/SL1100
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define the various basic tim-
Program
ers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
81
Input Data
Item No.
01
02
03
04
05
06
07
08
09
10
11
12
2-442
Downloaded from
www.Manualslib.com
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Layer 3 Timer Type Number
Item
Description
T301
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
ALERT message is received.
T302
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is sent. Timer is also restarted
when INFO is received.
T303
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent.
T304
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is received. Timer is also re-
started when INFO is received.
T305
Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC without progress No. 8 is sent.
T306
Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC with progress indicator No. 8 is sent.
This timer is valid for Network side use
only.
T307
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND ACK is sent. This timer is valid
only for Network side use only.
T308
Specifies the timer value in 1/100ths of a
second of the timer to be started when
REL is sent.
T309
Specifies the timer value in 1/100ths of a
second upon data link disconnection.
T310
Specifies the timer value in 1/100ths of a
second of the timer to be started when
CALL PROC is sent.
T312
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent or re-sent on broadcast
data link. This timer is only valid for Net-
work side use only.
T313
Specifies the timer value in 1/100ths of a
second of the timer to be started when
connection request is sent. Valid range 1 ~
4 seconds in 1 second increments. Value
of 0 indicates timer not used.
manuals search engine
1 ~ 5
Input Data
0, 180 ~ 254 seconds
1 ~ 254 seconds
1 ~ 254 seconds
0 ~ 254 seconds
1 ~ 254 seconds
0 ~ 254 seconds
1 ~ 254 seconds
1 ~ 254 seconds
1 ~ 254 seconds
0 ~ 180 seconds
1 ~ 254 seconds
1 ~ 254 seconds
Program 81 : Basic Hardware Setup for Trunk
ISSUE 1.0
Default
180 seconds
15 seconds
4 seconds
30 seconds
30 seconds
30 seconds
180 seconds
4 seconds
90 seconds
180 seconds
6 seconds
4 seconds