SL1000/SL1100
Alarm
No.
3
Program
90
4
2-512
Downloaded from
www.Manualslib.com
Re-
Type
Name
port
2
0
Connection
The error occurred
fault be-
when communicat-
tween CPU
ing with the pack-
and other
PKGs.
When the package
is broken, it recog-
nizes it as a com-
munication fault.
2
0
PKG S/W
The unit program
Download
could not be down-
Error
loaded normally.
The unit could not
able to be started
manuals search engine
Content of
Cause
Alarm
1 The unit is not
completely in-
serted.
age.
2 The power-
supply voltage
of the system
is outside rat-
ings.
3 The equipment
that generates
the noise in the
same power
supply system
as the power
supply origin of
the system is
connected, and
it malfunctions
because of the
power supply
noise.
4 The equipment
to which it is
adjacent to of a
main device,
and has put
out the radia-
tion noise ex-
ists, and it
malfunctions
because of the
radiation noise.
5 The chassis is
not properly
grounded.
1 The package
software is not
stored in the
downloaded
USB memory.
normally.
2 The stored
package soft-
ware is illegal.
Package infor-
mation that
was installed
before re-
mains.
Program 90 : Maintenance Program
ISSUE 1.0
Action
Recovery
Status
1 Please insert
When unit is
the unit firmly.
confirmed,
2 The power-
the error is
supply voltage
recovered.
must use an-
other power
supply when is
in the range of
ratings or mea-
suring with the
voltmeter, and
deviating from
the rated range.
3 Please use the
power supply
besides the
equipment with
the possibility of
the noise
source.
4 Please sepa-
rate as much as
possible and
use a main de-
vice from the
equipment by
which you seem
may generate
the radiation
noise.
5 Please ground
the chassis cor-
rectly.
1 Delete slot in-
Please ex-
formation that
change
corresponds by
units,
Program 90-05-
though it is
01 to delete
likely to re-
package infor-
store by
mation that was
mounting
installed before.
the unit
2 There is a pos-
again.
sibility that the
When the
unit program is
unit program
broken though
is normally
an external fac-
down-
tor of the noise
loaded, the
etc. is thought.
error is re-
3 Please load into
covered.
the USB
memory and try
again when you
back up the unit
program.
4 Please Check
with maker on
uncertain
points.