ISSUE 1.0
Level
IN
Description
Use Program 15-22 : Mobile Extension Setup to set the system information for the Mobile Extension
feature.
Input Data
Item No.
01
02
03
04
Conditions
None
Feature Cross Reference
None
Programming Manual
Downloaded from
www.Manualslib.com
Program 15 : Extension, Basic Setup
Extension Number
Item
Mobile Extension Target Setup
Set which Speed Dial bin is used to call when
the Mobile extension is called.
Connect Confirmation
Select when a confirmation (dial
to allow the call to cut over to the called mobile
number.
Trunk Access Code
Select if the Normal (0) or Individual (1) Trunk
access is used when making the call to the mo-
bile number.
Call Back
manuals search engine

15-22 : Mobile Extension Setup

Up to four digits (SL1000)
Up to eight digits (SL1100)
Input Data
0 ~ 999 (0 = No setting/1 ~ 999 = target
of mobile extension)
0 = Always
) is required
1 = On Analog Line
*
2 = Never
0 = Use normal trunk access code (Pro-
gram 11-09-01)
1 = Use individual trunk access code
(Program 11-09-02)
0 = Disable
1 = Enable
SL1000/SL1100
Program
15
Default
0
0
0
0
2-149