Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Input Data
Item
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Programming Manual
Downloaded from
www.Manualslib.com
Name
Answer Signal Detection Time (Loop)
Answer Signal Detection Time (Ground)
Answer Signal Detection Time (DID)
Answer Signal Detection Time (E&M)
Answer Signal Detection Time (OPX)
Clear Signal Detection Time (Loop)
Clear Signal Detection Time (Ground)
Clear Signal Detection Time (DID)
Answer Signal Detection Time (E&M)
Clear Signal Detection Time (OPX)
Ringing Signal Detection Time (Loop)
Ringing Signal Detection Time (Ground)
Ringing Signal Detection Time (DID)
Ringing Signal Detection Time (E&M)
Ringing Signal Detection Time (OPX)
Ringing Signal Stop Detection Time (Loop)
Ringing Signal Stop Detection Time
(Ground)
Ringing Signal Stop Detection Time (DID)
Ringing Signal Stop Detection Time (E&M)
Ringing Signal Stop Detection Time (OPX)
Loop Current Detection Time (Loop)
Loop Current Detection Time (Ground)
Loop Current Detection Time (DID)
Loop Current Detection Time (E&M)
Loop Current Detection Time (OPX)
DP Break Send Time (ALL)
DP Make Send Time (ALL)
DP InterDigit Send Time (ALL)
HookFlash Send Time (Loop)
HookFlash Send Time (Ground)
HookFlash Send Time (DID)
manuals search engine

81-08 : T1 Trunk Timer Setup

Input Data
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
SL1000/SL1100
Program
81
Default
15 (60 ms)
15 (60 ms)
15 (60 ms)
15 (60 ms)
15 (60 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
40 (160 ms)
40 (160 ms)
40 (160 ms)
40 (160 ms)
40 (160 ms)
15 (60 ms)
10 (40 ms)
7 (700 ms)
5 (500 ms)
5 (500 ms)
5 (500 ms)
2-445