ISSUE 1.0
Level
IN
Description
Use Program 22-09 : DID Basic Data Setup to define the basic setting of Dial-In incoming calls for
each trunk group.
Input Data
Item No.
01
02
03
04
05
06
07
08
Conditions
None
Feature Cross Reference
• Direct Inward Dialing (DID)
Programming Manual
Downloaded from
www.Manualslib.com
Program 22 : Incoming Call Setup
Trunk Group Number
Item
Expected Number of Digits
Enter the number of digits the
table expects to receive from the
Telco. Use this program to make
the system compatible with 3-
and 4-digit DID service. If ISDN
trunks, we analyze the last digits
that are set here. If it is T-1 or
analog DID, it analyzes the first
digits that are assigned here.
Received Vacant Number Op-
eration
Use this option to enable or dis-
able Vacant Number Intercept.
Sub-Addressing Mode
DID Receiving Mode for ISDN
Local Code Digits
(Only Overlap Receiving Mode)
Local Code
(Only Overlap Receiving Mode)
Pilot Code
(Only Overlap Receiving Mode)
T302 Time-out Operation
(Only Overlap Receiving Mode)
manuals search engine

22-09 : DID Basic Data Setup

Input Data
1 ~ 8
0 = Disconnect (Cut)
1 = Transfer (Refer to
Program 22-12 : DID In-
tercept Ring Group. on page
2-258)
0 = Extension # Specify (Intercom)
1 = DID Conversion Table
0 = Enbloc Receiving
1 = Overlap Receiving
0 ~ 15 (0 = No Local Code)
Dial (maximum 16 digits)
Dial (1 digit : 0 ~ 9)
0 = Disconnect (Cut)
1 = Transfer (Refer to
Program 22-12 : DID In-
tercept Ring Group. on page
2-258)
2 = Search
SL1000/SL1100
01 ~ 25
Default
2
0
0
0
0
No setting
No setting
0
2-253
Program
22

Hide quick links: