Ring Cycle Setup; Table 2-4 Ringing Cycles - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Level
IN
Description
Use Program 20-15 : Ring Cycle Setup to define the ringing cycles for each ring type.
Program
Input Data
20
Item No.
01
02
03
04
05
06
07
08
09
10
11
Conditions
None
2-182
Downloaded from
www.Manualslib.com
Program 20 : System Option Setup
Incoming Signal Type
Normal Incoming Call on Trunk
PBX, CES Incoming Call
Incoming Internal Call
DID/DISA/VRS
DID/DDI
Dial-In in the E&M Tie Line
Door Box Ringing for SLT
Virtual Extension Ring
Callback
Alarm for SLT
VRS Waiting Message Incoming Call
Number
1
On
2
On : 2.0 / Off : 4.0
3
On : 1.0 / Off : 2.0
4
On : 0.5 / Off : 0.5
5
On : 0.25 / Off : 0.25
6
On : 0.5 / Off : 0.5 / On : 0.5 / Off : 1.5
7
On : 0.25 / Off : 0.25 / On : 0.25 / Off : 5.25
8
On : 0.375 / Off : 0.25 / On : 0.375 / Off : 2.0
9
On : 0.25 / Off : 0.125 / On : 0.25 / Off : 0.125 / On : 0.25 / Off : 2.0
10
On : 1.0 / Off : 4.0
11
On : 0.25 / Off : 0.25 / On : 0.25 / Off : 4.25
12
On : 1.0 / Off : 3.0
13
On : 0.25 / Off : 0.25 / On : 0.25 / Off : 2.25
manuals search engine

20-15 : Ring Cycle Setup

Ringing Cycle

Table 2-4 Ringing Cycles

Ringing Cycle
ISSUE 1.0
Default
3
8
8
8
8
1 ~ 13
8
2
8
4
5
6
Program 20 : System Option Setup

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents