Description
Use Program 21-01 : System Options for Outgoing Calls to set the system options for Outgoing
Call Service.
Input Data
Item No.
01
02
03
04
05
06
07
08
09
Programming Manual
Downloaded from
www.Manualslib.com

Program 21 : Outgoing Call Setup

21-01 : System Options for Outgoing Calls

Item
Seizure Trunk Line Mode
Select the trunk based off the
Trunk Route Priority (0) or based
off the trunk that has not been
used in the longest time (1).
Intercom Interdigit Time
When placing Intercom calls, ex-
tension users must dial each digit
in this time.
Trunk Interdigit Time (External)
The system waits for this time to
expire before placing the call in a
talk state (Call Timer starts after
time expires, Voice Over and
Barge-In is not allowed until after
time expires).
Dial Tone Detection Time
If dial tone detection is enabled,
the system waits this time for the
Telco to return dial tone. When the
time expires, the system assumes
dial tone is not present. To disable
this time (and have the system wait
continuously), enter 0.
Disconnect Time when Dial Tone
not Detected
If 14-02-11 is enabled, the system
skips over a trunk if dial tone is not
detected. This option pertains to
calls placed using Speed Dial,
ARS, Last Number Redial or Save
Number dialed. It does not pertain
to line key or Direct Trunk Access
calls.
Dial Pause at First Digit
Toll Restriction Override Time
After dialing the Toll Restriction
Override codes, the system re-
moves Toll Restriction from the
extension for this time.
Preset Dial Display Hold Time
Ringdown Extension Timer
(Hotline Start)
A Ringdown extension automati-
cally calls its programmed destina-
tion after this time.
manuals search engine
Input Data
0 = Priority Route
1 = Circular Route
0 ~ 64800 seconds
10 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
5 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
10 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
5 seconds
SL1000/SL1100
Default
Related Program
0
14-05
14-06
10
14-02-08
14-02-05
0
3
20-08-06
21-07
5
20-08-09
21-11
2-217