Program 20 : System Option Setup; System Options - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 1.0
Level
IN
Description
Use Program 20-01 : System Options to set various system options.
Input Data
Item
No.
01
02
05
06
07
08
09
10
12
16
17
Conditions
None
Feature Cross Reference
None
Programming Manual
Downloaded from
www.Manualslib.com

Program 20 : System Option Setup

Item
Input Data
Operator Access
0 = Step Call
Mode
1 = Circular
Text Message Mode 0 = Call mode
1 = No Answer/
Busy mode
DTMF Receive Ac-
0 ~ 64800 seconds
tive Time
Alarm Duration
0 ~ 64800 seconds
Callback Ring Dura-
0 ~ 64800 seconds
tion Time
Trunk Queuing Call-
0 ~ 64800 seconds
back Time
Callback/Trunk
0 ~ 64800 seconds
Queuing Cancel
Time
Trunk Guard Timer
0 ~ 64800 seconds
Telephone/Web Pro
1 ~ 86400
Logout Time
(86400 seconds = 1
day)
Mobile Extension
1 ~ 64800 seconds
Callback time
Day/Night Change
0 = Toggle
Key Mode
1 = Skip
manuals search engine

20-01 : System Options

Default
Description
0
Use this program to set up
priority of a call when calling
an operator telephone.
0
Use this program to select the
mode when calling the tele-
phone which set up the text
message.
10 seconds
For OPXs, analog telephones
and certain analog trunks (like
DISA), the system attaches a
DTMF receiver to the port for
this time. The system releases
the receiver after the time ex-
pires.
30 seconds
This time sets the duration of
the alarm signal.
15 seconds
Callback rings an extension
for this time.
15 seconds
Trunk Queuing callback rings
an extension for this time.
64800 seconds
The system cancels an exten-
sion Callback or Trunk Queu-
ing request after this time.
1 seconds
The amount of time the sys-
tem waits to seize the next
outside line after the system
releases an outside line.
900 seconds
The system automatically logs
(15 min.)
out of a Telephone/Web Pro
session after inactivity lasting
this time.
15 seconds
The amount of time the sys-
tem waits to until system ends
the call back.
0
Sets the operation mode for
15-07 (Code 09) Day/Night
Mode Switch.
SL1000/SL1100
Program
Related Pro-
20
gram
20-17
11-11-14
15-07-08
25-07-01
11-11-12
11-12-05
15-07-35
11-12-05
15-07-35
11-12-05
15-07-35
15-22-04
15-07
2-155