Solar-Log 200 Installation Manual page 133

Hide thumbs Also See for 200:
Table of Contents

Advertisement

Note!
Click on this
recorded by the Solar-Log™ and to display the target state.
Switch states / Color Definition
The switching state of each contact is displayed with the following symbols:
Symbol
Explanation Text
Target state: On
Actual state: On
Everything OK
Target state: Off
Actual state: Off
Everything OK
Target state: On
Actual state: Off
Target state: Off
Actual state: On
Switch state: None
Actual state: Unknown
Target state: On
Actual state: Unknown
Error
Target state: Off
Actual state: Unknown
Error
Target state: None
Actual state: On
Everything OK
Target state: None
Actual state: Off
Everything OK
The current switching states are display within a few second and are continuously updated.
symbol to display all of the hardware data that can be accessed and
Notes
If the hardware does not support the current state being read, this
symbol is also used to clearly identify a fault case.
If the hardware does not support the current state being read, this
symbol is also used to clearly identify a fault case.
For example: The Solar-Log™ determined that the switch should be
activated (e.g. surplus reached), but the command was not sent to
the switch. This can only happen when the switching state can be
read.
=> This state is temporarily valid, but not a longer period without a
change.
(e.g. the switch does not accept the switching command.)
For example: The Solar-Log™ determined that the switch should be
deactivated (e.g. surplus too low), but the command was not sent
to the switch. This can only happen when the switching state can be
read.
=> This state is temporarily valid, but not a longer period without a
change.
(e.g. the switch does not accept the switching command.)
The switch is not assigned to a group.
=> No target state
The switch state cannot be read or the switch is not available.
=> If no state can be read (hardware does not support this), every-
thing is ok.
=> Otherwise the hardware is not available (fault).
The switch state can be read, but the hardware is unavailable.
The switch state can be read, but the hardware is unavailable.
The switch can be read, but the switch is not assigned to a group.
=> No target state
The switch can be read, but the switch is not assigned to a group.
=> No target state
Smart Energy
133

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 200 and is the answer not in the manual?

Questions and answers

Related Products for Solar-Log 200

This manual is also suitable for:

300500100012002000250

Table of Contents