Precision stop OFF G8

G8 switches Precision stop off. The block containing G8 is executed
without a Precision stop.

Precision stop blockwise G9

G9 activates a Precision stop for the NC block in which it is
programmed. With a Precision stop, the control does not run
the following block until the last point has been reached in the
tolerance window for position. The tolerance window is defined in
the posTolerance machine parameter (no. 401101).

Switch off protection zone G60

G60 is used to cancel protection zone monitoring. G60 is
programmed before the traversing command to be monitored or
not monitored.
Parameters:
Q: activate/deactivate – Self-locking=1
0: Activate protection zone (modal)
1: Deactivate protection zone (modal)
Application example: With G60, you can temporarily deactivate a
programmed monitoring of the protection zone in order to machine
a centric through hole.
Example: G60
. . .
N1 T4 G97 S1000 G95 F0.3 M3
N2 G0 X0 Z5
N3 G60 Q1
N4 G71 Z-60 K65
N5 G60 Q0
. . .

Actual values in variable G901

G901 transfers the actual values of all the axes of a slide into the
variables for the interpolation information.
Further information:

Datum in variable G902

G902 transfers the datum shifts into the variables for the interpolation
information.
Further information:
440
"Fill variable memory G904", Page 441
"Fill variable memory G904", Page 441
DIN/ISO programming | Other G codes
Deactivate protection zone
Activate protection zone
HEIDENHAIN | User's Manual smart.Turn and DIN Programming | 12/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Manualplus 620

Table of Contents