Appendix A—Technical Data and Specifications
Appendix A—Technical Data and Specifications
Table 28. PowerXL Series—DG1
Attribute
Description
Input ratings
Input voltage U in
Input frequency
Connection to power
Starting delay
Short-circuit withstand rating
Output ratings
Output voltage
Continuous output current
Overload current
Initial output current
Output frequency
Frequency resolution
Control characteristics
Control methods
Switching frequency
Frequency reference
Field weakening point
Acceleration time
Deceleration time
Braking torque
Ambient conditions
Ambient operating temperature
Storage temperature
Relative humidity
Air quality:
Chemical vapors
Mechanical particles
Altitude
Vibration:
EN 61800-5-1
EN 60668-2-6
44
DG1 Series VFD MN040002EN—March 2014 www.eaton.com
Specification
208V to 240V, 380V to 500V, 525V to 600V, –15 to 10%
50 Hz to 60 Hz (variation up to 45 Hz to 66 Hz)
Once per minute or less
3 s (FR1 to FR2), 4 s (FR3), 5 s (FR4), 6 s (FR5)
100 kAIC
0 to U in
IL: ambient temperature maximum 40°C, up to 60°C with derating, overload 1.1 x IL (1 min./10 min.)
IH: ambient temperature maximum 50°C, up to 60°C with derating, overload 1.5 x IH (1 min./10 min.)
150% respectively 110% (1 min./10 min.)
200% (2 s/20 s)
0–400 Hz (standard)
0.01 Hz
Frequency control
Speed control
Open-loop speed control
Open-loop torque control
Range:
FR1–3: 1 kHz to 12 kHz
FR4–5: 1 kHz to 10 kHz
Defaults:
FR1–3: 4 kHz (IH), 6 kHz (IL)
FR4–5: 3.6 kHz
Automatic switching frequency derating in case of overload.
Analog input: resolution 0.1% (10-bit), accuracy +1%
Panel reference: resolution 0.01 Hz
20 Hz to 400 Hz
0.1 s to 3000 s
0.1 s to 3000 s
DC brake: 30% x Motor Rated Torque (Tn) (without brake chopper)
Dynamic braking (with optional brake chopper using an external brake resistor):
100% continuous maximum rating
–10°C (no frost) to +50°C, up to +60°C with derating (CT)
–10°C (no frost) to +40°C, up to +55°C with derating (VT)
–40°C to +70°C
0–95% RH, noncondensing, non-corrosive
Tested according to IEC 60068-2-60 Test Key:
Flowing mixed gas corrosion test, Method 1 (H2S [hydrogen sulfide] and SO2 [sulfur dioxide])
Designed according to:
IEC 60721-3-3, unit in operation, class 3C2
IEC 60721-3-3, unit in operation, class 3S2
100% load capacity (no derating) up to 3280 ft (1000 m); 1% derating for each 328 ft (100 m) above
3280 ft (1000 m); max. 9842 ft (3000 m) (2000 m for corner grounded earth main systems)
5–150 Hz
Displacement amplitude: 1 mm (peak) at 5 Hz to 15.8 Hz (FR1–FR5)
Maximum acceleration amplitude: 1g at 15.8 Hz to 150 Hz (FR1–FR5)