Fpσ Compatible Instruction Mode Control Instruction; F171(Spdh)] Pulse Output (Trapezoidal Control) - Panasonic FP0H User Manual

Control unit positioning/pwm output/high-speed counter
Hide thumbs Also See for FP0H:
Table of Contents

Advertisement

Instruction References
7.2 FPΣ Compatible Instruction Mode Control Instruction

7.2.1 [F171(SPDH)] Pulse Output (Trapezoidal Control)

This instruction outputs pulses from a specified pulse output channel according to specified
parameters.
 Instruction format
R0
DF
 Operand
Operand
Settings
S
Starting number of the area in which data tables are registered
n
Target channel for pulse output
 Memory area type that can be specified
Operand
WX
WY
S
-
n
-
 Outline of operation
• Outputs pulses from a specified channel when a corresponding control active flag is OFF
and the execution condition is ON.
• The control code, initial speed, maximum speed, acceleration/deceleration time, and target
value are specified by creating data tables [S] to [S+11] described on the next page using a
user program.
• Switches the frequency from the initial speed to the maximum speed in the specified
acceleration/deceleration time. At the time of deceleration, switches the frequency with the
same inclination as that for acceleration.
• For setting the frequency to 50 kHz or more, specify the duty of 1/4 (25%).
7-8
F171 SPDH
WR
WL
SV
-
-
-
-
-
-
-
-
S
n
EV
DT
LD
I
-
A
-
-
-
-
-
-
Constant
Index
modifier
K
H
-
-
A
A
A
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents