5.5 Repeat Operation
5.5.1 Overview of Repeat Operation
• The repeat count is specified for executing the repeat control in Configurator PMX.
• When the position control start instruction F380 is executed, the unit repeats the operation
set in the positioning table.
Conditions of repeat control
Item
Repeat control is available
E-point control, P-point control + E-point
control
Operation pattern
C-point control + E-point control
Control method
Increment mode
Set the table of E-point control to 1 ms or
Dwell time setting
more.
Operation diagram (Setting operation on the table)
Operation diagram (Repeat operation)
5.5 Repeat Operation
Repeat control is unavailable
JOG operation, J-point control, Interpolation
control
Absolute mode
When setting 0 ms.
5-29