Control unit positioning/pwm output/high-speed counter
Hide thumbs Also See for FP0H:
Table of Contents

Advertisement

Instruction References
Operand
S+8, S+9
 Example of program
R0
R1
DF
 Regarding the specification of acceleration/deceleration time
For specifying acceleration/deceleration time, No. of steps and initial speed, set the value to
be calculated by the formula below. Specify acceleration/deceleration time in 30 ms
increments with 30 steps, and in 60 ms increments with 60 steps. When the time is not
specified in 30 ms nor 60 ms increments, it will be automatically corrected to the multiple
values (larger value) of 30 ms or 60 ms.
Acceleration/deceleration time t[ms] ≥ (No. of steps x 1000)/Initial speed f0[Hz]
• When "Acceleration/deceleration time priority" is specified for the control code, the initial
speed is corrected according to the time.
The corrected speed is stored in the correction speed area of initial speed of special data
registers (from DT90400).
(Example): When the initial speed is 10 Hz, and acceleration/deceleration time is 1 msec,
the initial speed is corrected to 1000 Hz.
• When the corrected initial speed exceeds the maximum speed, the initial speed is corrected
to the maximum speed.
(Example): When the initial speed is 10 Hz, the maximum speed is 500 Hz,
acceleration/deceleration time is 1 msec, and acceleration/deceleration time priority is
specified, it takes 100 msec for outputting one pulse at the initial speed and it exceeds 1
msec of acceleration/deceleration time.
Although the initial speed is corrected to 1000 Hz as "Acceleration/deceleration time priority"
is specified, it is corrected to 500 Hz because it exceeds the maximum speed.
 Supplement to pulse output operation
When outputting pulses with the PLS+SIGN (direction output) method, pulses will be output
approx. 300µs later after the output of direction signal (SIGN). (The characteristics of a motor
driver are considered.)
7-16
Settings
Description
Set the output time of the deviation counter clear signal.
Deviation counter
0.5 ms to 100 ms [K0 to K100] Setting value + error (0.5 ms or
clear signal output
less)
time
When this signal is not used or the time is set to less than 0.5 ms,
tr(ms)
specify K0.
F1 DMV
H1125
F1 DMV
K1000
F1 DMV
K7000
F1 DMV
K100
F1 DMV
K10
F171 SPDH
DT0
DT0
DT2
DT4
DT6
DT8
K2