Panasonic FP0H User Manual page 15

Control unit positioning/pwm output/high-speed counter
Hide thumbs Also See for FP0H:
Table of Contents

Advertisement

 Input signals of Control Unit
I/O
Pulse output function
no.
CH0 J-point positioning start
X0:
input
CH1 J-point positioning start
X1
input
X2
CH0 Home input
CH2 J-point positioning start
X3
input
CH3 J-point positioning start
X4
input
X5
CH1 Home input
X6
CH2 Home input
X7
CH3 Home input
(Note 1): When the reset input settings of reset input for the single-phase input overlap at CH0 and CH1 or CH2 and
CH3, the setting of CH1 or CH3 has priority.
 Output signals of Control Unit
Pulse output function
I/O
no.
Pulse output
Y0
CH0 CW or pulse output
Y1
CH0 CCW or sign output
Y2
-
Y3
CH1 CW or pulse output
Y4
CH1 CCW or sign output
Y5
-
Y6
-
Y7
-
Y8
CH2 CW or pulse output
Y9
CH2 CCW or sign output
YA
-
YB
CH3 CW or pulse output
YC
CH3 CCW or sign output
YD
-
YE
-
YF
-
(Note 2): When using the PWM output, the output numbers to be paired are normal output.
(Note 3): When using the target value match ON instruction (F166) or target value match OFF instruction (F167) in
the high-speed counter function, arbitrary output is specified in the range of Y0 to Y1F in a user program so
that it does not overlap the above functions.
1.2 Restrictions on Combinations and Functions
High-speed counter function
Count input
Single-phase
2-phase
CH0 Count input
CH0 Count input
CH1 Count input
-
-
CH2 Count input
CH2 Count input
CH3 Count input
-
-
-
-
-
-
Deviation counter clear
-
-
CH0
-
-
CH1
-
-
-
-
CH2
-
-
CH3
-
-
Reset input
-
-
CH0, CH1 Reset input
-
-
CH2, CH3 Reset input
-
-
PWM output
CH0
(Note 2)
-
CH1
(Note 2)
-
-
-
CH2
(Note 2)
-
CH3
(Note 2)
-
-
-
1-5