Verifying Rack Suitability; Choosing The Type Of Rack; Making Space For The Scopia Tip Gateway - RADVision SCOPIA TIP Deployment Manual

Hide thumbs Also See for SCOPIA TIP:
Table of Contents

Advertisement

Note
Before proceeding with the installation, verify that all of the ordered parts are present and in
good condition. Keep a record of the parts and serial numbers. If any parts are missing or
damaged, contact your sales representative.

Verifying Rack Suitability

There are some critical requirements that you must meet when choosing a rack and before
mounting the device into it.

Choosing the Type of Rack

There are many types of racks on the market. The installation instructions in this guide are
intended for a 19" rack.

Making Space for the SCOPIA TIP Gateway

When checking for an empty space to setup the device, be aware of its physical dimensions.
RADVISION | Deployment Guide for SCOPIA TIP Gateway Version 8.0
Choosing the Type of Rack ................................................................ page 10
Making Space for the SCOPIA TIP Gateway .............................................. page 10
Verify that the 19" rack meets the EIA-310 standards. This standard includes precise
definitions of the shape of the holes, their size, the depth of the rack and other features.
For more information on the EIA-310 standard, see
http://electronics.ihs.com/collections/eia/index.htm
Notice that the vertical square holes on the rack posts are not spaced equally. They form
a repeating pattern of two holes close together, then one hole separate, then two holes
close together and so on. See
Figure 3-2
Install the device in an open rack whenever possible. If installation in an enclosed rack is
unavoidable, ensure that the rack has adequate ventilation.
Figure 3-2 on page
10.
Hole distribution on 19" rack
Preparing the SCOPIA TIP Gateway Setup | 10