Step 5
Step 6
Step 7
Step 8
Step 9
RADVISION | Deployment Guide for SCOPIA TIP Gateway Version 8.0
Table 4-1
Configuring the communication settings
Field Name
Baud Rate
Data bits
Parity
Stop bits
Flow Control
Press the On/Off switch on the front side of the device (see
power on the device.
Verify the power LED is lit green.
A log of the auto-boot events is displayed in the terminal emulator.
When the message Press any key to start configuration appears on the screen,
press a key and wait for the following message:
Main menu
If you do not see this output, contact customer support.
Enter N at the prompt to configure network port values.
The terminal displays the following message:
Configure network port values
1: Show current network configuration
2: Change network configuration
0: Return to main menu
Select:
Enter 2 to change the network configuration.
Enter the new information at each prompt:
IP address
Value
9600
8
None
1
None
Figure 4-10
Device front panel
Figure 4-10 on page
21) to
Setting up the SCOPIA TIP Gateway | 21