11. Click In-Band Parameters if you want to allow in-band access for this Serial port.
12. Click on the In-band application drop-down arrow and select either RemoteDesktop
Viewer, SSH Client, VNC Viewer. Type the IP address of the target associated with this
port in the Target IP Address field, type the port used by the In-band application in Target
TCP Port, and type a username that is used to login to the in-band application in the Target
Username field. Click OK to save the In-band parameter settings or Cancel to exit without
saving.
13. Click OK to configure the serial port or Cancel to exit without configuring. A Port
Configured Successfully message confirms that the port has been created.
14. Repeat steps 1 through 11 to configure other serial ports.
Note: For KSX power ports and SX serial ports, associating a device with the port is available in
the Configure Serial screen and not in the In-Band parameters screen.