Connection Of D-Sub Connector Pins; Connection - YASKAWA DX100 Instructions Manual

Options, for data transmission function
Hide thumbs Also See for DX100:
Table of Contents

Advertisement

Data Transmission
Function

2.4.9 Connection of D-SUB Connector Pins

2.4.10 Connection

2
For Using Data Transmission Function
2.4 Transmission Specifications
The connection of D-SUB connector pins is shown below.
Fig. 2-2: YCP01 board (D-SUB9P)
CD
RD
SD
ER
SG
RS
CS
FG
Since the system is "null-modem", connect the pins as shown below.
Fig. 2-3: YCP01 board
Host Computer
SD
3
RD
2
RS
7
CS
8
SG
5
• Connect "RS" of the DX100 to "CS" of a host computer.
This prevents data overrun when reception processing speed of the
DX100 cannot catch up with data sending from the host computer.
In other words, "RS" signal from the DX100 controls start-hold of
data transmission from the host computer.
The sending interface controller must be capable of coping with CS
input displacement in units of a single byte.
• The DX100 sends data when the "CS" signal is ON.
2-12
DX100
1
Carrier detect
2
Data receive
3
Data send
4
Data terminal ready
5
Grounding for signal
7
Request to send
8
Sending enabled
9
Protective grounding
157449-1CD
DX100
RD
2
3
SD
5
SG
RS
7
CS
8
FG
9
28 of 125
RE-CKI-A456

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents