Data Transmission
Function

5.2.7 I/O Read/Write Function

5.2.7.1 Transmission Procedure

5
Host Control Function of DX100
5.2 Robot Control Function
The host control function can read out or write in (change) I/O signal
status using the host computer.
The following table shows the number of signals and the types of signals
to be sent or received by the host control function.
 : Possible to execute
Signal
Signal Range (Qty)
0xxxx
00010 to 02567 (2048)
1xxxx
10010 to 12567 (2048)
2xxxx
20010 to 22567 (2048)
3xxxx
30010 to 32567 (2048)
4xxxx
40010 to 41607 (1280)
5xxxx
50010 to 52007 (1600)
7xxxx
70010 to 79997 (7992)
8xxxx
80010 to 80647 (512)
82xxx
82010 to 82207 (160)
25xxx
25010 to 27567 (2048)
The transmission from the host computer proceeds as follows.
1. The ENQ code is sent from the host computer to establish a data link.
2. After the data link is established, the data is sent from the host
computer. The data transmission should be completed in a single
block.
3. After the request to send is accepted, the host computer should be
ready to receive.
The DX100 sends the ENQ code to establish the data link.
4. After the data link is established, the data sent from the DX100 is
received to terminate the transmission at completion of receipt.
The read/write function can be distinguished by the header number.
Refer to the header number list.
5-47
Classification
Read-out Write-in
General input signal
¡
General output signal ¡
External input signal
¡
External output signal ¡
Specific input signal
¡
Specific output signal
¡
Auxiliary relay
¡
Control status signal
¡
Pseudo input signal
¡
Network input
¡
RE-CKI-A456
157449-1CD
¡