AudioCodes Mediant 500L User Manual page 1243

Enterprise session border controller (e-sbc) & media gateway
Hide thumbs Also See for Mediant 500L:
Table of Contents

Advertisement

User's Manual
Parameter
[AMDTimeout]
AMD Beep Detection Mode
configure voip > sip-definition
settings > amd-beep-detection
[AMDBeepDetectionMode]
Answer Machine Detector Beep
Detection Timeout
configure voip > media ipmedia >
amd-beep-detection-timeout
[AMDBeepDetectionTimeout]
Answer Machine Detector Beep
Detection Sensitivity
configure voip > media ipmedia >
amd-beep-detection-sensitivity
[AMDBeepDetectionSensitivity]
early-amd
[EnableEarlyAMD]
AMD Mode
configure voip > sip-definition
settings > amd-mode
[AMDmode]
Version 7.2
AMDMaxGreetingTime) until the device's AMD decision. You
can also configure this functionality per specific calls, using IP
Profiles (IpProfile_AMDMaxPostSilenceGreetingTime). For a
detailed description of the parameter and for configuring this
functionality in the IP Profiles table, see ''Configuring IP
Profiles'' on page 438.
Note: If this functionality is configured for a specific IP Profile,
the settings of this global parameter is ignored for calls
associated with the IP Profile.
Defines the timeout (in msec) between receiving Connect
messages from the Tel side and sending AMD results.
The valid range is 1 to 30,000. The default is 2,000 (i.e., 2
seconds).
Determines the AMD beep detection mode. This mode detects
the beeps played at the end of an answering machine
message, by using the X-Detect header extension. The device
sends a SIP INFO message containing the field values
Type=AMD and SubType=Beep. This feature allows users of
certain third-party, Application server to leave a voice message
after an answering machine plays the "beep".
[0] Disabled (default)
[1] Start After AMD
[2] Start Immediately
Defines the AMD beep detection timeout (i.e., the duration that
the beep detector functions from when detection is initiated).
This is used for detecting beeps at the end of an answering
machine message.
The valid value is in units of 100 milliseconds, from 0 to 1638.
The default is 200 (i.e., 20 seconds).
Defines the AMD beep detection sensitivity for detecting beeps
at the end of an answering machine message.
The valid value is 0 to 3, where 0 (default) is the least sensitive.
Enables AMD detection to be activated upon receipt of an
ISDN Alerting or Connect message.
[0] = (Default) Disable - AMD is activated upon receipt of
ISDN Connect message.
[1] = Enable - AMD is activated upon receipt of ISDN
Alerting message.
Global parameter that enables the device to disconnect the IP-
to-Tel call upon detection of an answering machine on the Tel
side. You can also configure this functionality per specific calls,
using IP Profiles (IpProfile_AmdMode). For a detailed
description of the parameter and for configuring this
functionality in the IP Profiles table, see ''Configuring IP
Profiles'' on page 438.
Note: If this functionality is configured for a specific IP Profile,
the settings of this global parameter is ignored for calls
1243
69. Configuration Parameters Reference
Description
Mediant 500L Gateway & E-SBC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents