Disarming Under Duress - Technoalarm TP4-20 User Manual

4 to 20 zones control panel
Table of Contents

Advertisement

WARNING
Whereas the master code is always enabled for all the programs, the user codes control merely the
programs they have been enabled for by the installer or the holder of the master code.
WARNING
The zones excluded are those associated to the bypass function and included in the program
selected.
WARNING
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect.
When trying to do so, the system ignores the command.
The green LED 5 remains lit and the red program LED remain off.
After 5 seconds, the electronic keypad returns to stand-by.
TP4-20 - User Manual
5.2.2
DISARMING
5.2.2.1
DISARMING WITH CODE
Enter a valid code (master or standard user code enabled for the programs armed),
e.g. master code (default code 12345):
+ 12345
The green LED 5 is lit.
For the 8 seconds to come it is possible to select the programs to be armed/disarmed
(pressing the program number the first time the program is selected, pressing it the
second time it is deselected). On every keystroke the counter is reset.
Select the programs to be disarmed, e.g.:
+ 1 3
After 8 seconds the corresponding red program LED are switched off and the
programs return to stand-by.
+ #
to confirm the selection and stop the counter without waiting for 8 seconds
5.2.2.2
DISARMING UNDER DURESS (IF ENABLED)
Under duress it is possible to simulate disarming of the system and release
simultaneously a silent hold-up alarm.
For this enter the master code or a standard user code (enabled for the programs
armed) reducing the last digit by one unit, e.g. master code (default code 12345):
+ 12344
The control panel is apparently disarmed, i.e. all the program LED are switched off,
and if programmed appropriately by the installer, the logic outputs OUT1 or OUT2 of
the CPU board and all the modules connected and a telephone call for hold-up alarm
are activated.
5.2.3
BYPASS
When the control panel is armed, it is possible to deactivate temporaneously part of
the system. Upon activation of the bypass, the zones enabled for bypass and included
in the program/s armed and partset are deactivated. The other zones are not affected.
The exclusion of zones persists until deactivation of the bypass or disarming of the
programs they are included in.
5.2.3.1
ACTIVATION OF BYPASS WITH CODE
Enter a code enabled for bypass (master or standard user code enabled for the
programs armed) followed by the number of the program to be partset, e.g.:
+ 66778
+ 1
For the time the bypass is active the corresponding program LED is blinking.
5.2.3.2
ACTIVATION OF BYPASS DURING THE ACCESS PERIODS
It is possible to define 2 access periods of the codes. As a consequence, the codes
are enabled for bypass during the access periods associated by the installer or holder
of the master code only.
Control by Keypoint and Wireless Key
5-7