Technoalarm TP4-20 User Manual page 38

4 to 20 zones control panel
Table of Contents

Advertisement

WL key 01
2
Ass. buttons
Ass. buttons
1
Button 01
Button 01
3
Arm. program
Arm. program
Program 01
Button 01
6
ON/OFF rem ctrl
ON/OFF rem ctrl
Rem. ctrl 01
Rem. ctrl 01
3
Attribute
Programming
3-12
FUNCTION KEYS
Every wireless key provides 3 function keys freely associable to various functions.
SELECTION OF THE FUNCTION KEY
+ wy
to select the key to be programmed
+ #
to confirm the selection
The following functions can be programmed:
Deactivated (key not associated to any function)
Total disarming (disarming of all the programs armed by this wireless key)
Arming program (arming of the program associated)
Disarming program (disarming of the program associated)
Activation/deactivation remote control (inversion of status of the remote control
associated, i.e. pressing the key the first time activates and the second time
deactivates the wireless key)
Activation remote control (activation of the function associated to the remote
control associated)
Deactivation remote control (deactivation of the function associated to the remote
control associated)
On the display is viewed current programming:
[
]
Function disabled
[ # ]
Function enabled
Commands available
+ wy
to select the function
+ #
to enable the function
+ *
to disable the function
+ CL-EX
to confirm and quit
PROGRAM
The association function key-program determines the program (1 to 4) that is armed
or disarmed on pressing of the function key selected.
Every key can be associated only one program to.
Commands available
+ wy
to select the program
+ #
to associate the program to the key selected
+ CL-EX
to confirm and quit
REMOTE CONTROL
The association function key-remote control determines the remote control (1 to 2)
that is activated or deactivated on pressing of the function key selected.
Every key can be associated only one remote control to.
Commands available
+ wy
to select the remote control
+ #
to associate the remote control to the key selected
+ CL-EX
to confirm and quit
ATTRIBUTE
The following functions can be programmed:
Bypass (enables the wireless key for the bypass of the program associated)
Bypass general alarms (enables the code for arming of the system in presence of
general alarms, i.e. tamper, low battery, power failure, supervision, trouble
modules)
Confirmation of disarming (hold-up block, i.e. on disarming with wireless key a
timer (programmable by the installer) is activated on rundown of which a hold-up
alarm is released unless a valid user code is entered on one of the consoles
connected)
Panic alarm (simultaneous pressing of the keys 2 and 3 of the wireless key
selected causes release of a panic alarm)
Automatic abort of disarming (enables the wireless key for the automatic block of
the alarm call cycles of all the active telephone channels and those waiting on
disarming of the system)
Disabling exclusion (disables the wireless key for the exclusion of zones
(manually or automatically) on disarming. In case of arming in presence of open
zones, these are activated and release the alarm.)
On the display is viewed current programming:
[
]
Function disabled
[ # ]
Function enabled
Commands available
+ wy
to select the function
+ #
to enable the function
User Manual - TP4-20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents