4
Outdoor siren
WARNING
During the test, the wireless sirens behave according to programming, i.e. deactivated, sounding
only, flashing light only, sounding and flashing light.
The sounding or flashing time programmed, however, is not considered during the test that has a fix
duration of 60 seconds unless it is interrupted by pressing CL-EX.
Programming
3-14
On the display is viewed current programming:
[
]
Device active/zone active
[ # ]
Device excluded/zone excluded
Commands available
+ wy
to select the number of the device/zone to be excluded
+ #
to exclude the device/zone selected
+ *
to enable the device/zone selected
+ CL-EX
to confirm and quit
3.1.12

FUNCTIONING TEST

From the master programming menu select the submenu test.
In the test menu the following tests can be initiated:
Zone test (test of opening of the zone inputs)
Indoor siren test (test of the indoor sirens)
Outdoor siren test (test of the outdoor sirens)
Version (viewing of the firmware version of the control panel)
Led console (test of the leds of the consoles)
GSM (test of the GSM telephone communicator)
Commands available
+ wy
to select the test/viewing to be initialized
+ #
to inicialize the test/viewing
3.1.12.1
ZONE TEST
The zone test permits verifying of smooth functioning of the wired zone inputs and of
the wireless zones.
On initiating the test, the control panel enters the wait mode and on the display is
viewed Zones followed by three hyphens (- - -).
Pass by the detectors or open the contacts.
For every zone found open, the buzzer on the consoles sounds for approximately
2 seconds.
After the test, the open zones can be viewed in sequence by pressing:
+ wy
to view the open zones
The test has no determined duration.
It is possible to interrupt the test at any time by pressing:
+ CL-EX
to interrupt the test and quit
3.1.12.2
INDOOR SIREN TEST
The indoor siren test permits the verification of smooth functioning of the sirens as
well as of battery charge of the control panel battery.
On initiating the test, the indoor sirens are activated and powered by battery.
After the test, if battery charge is too low, the battery led starts blinking. Verify the
battery of the control panel and if need be replace it.
The test takes 60 seconds.
It can be interrupted at any time by pressing:
+ CL-EX
to quit
3.1.12.3
OUTDOOR SIREN TEST
The outdoor siren test permits verifying of smooth functioning of the sirens as well as
of battery charge of the control panel battery.
On initiating the test, the outdoor sirens are activated and powered by battery.
After the test, if battery charge is too low, the battery led starts blinking. Verify the
battery of the control panel and if need be replace it.
The test takes 60 seconds.
It can be interrupted at any time by pressing:
+ CL-EX
to quit
User Manual - TP4-20