Arming
automatic
WARNING
Automatic arming is direct, i.e. the exclusion of zones is not possible.
It is always executed even in presence of trouble/general alarm or fault (low battery, power failure
etc.).
WARNING
Automatic arming can only be aborted by the holder of the master code.
WARNING
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect.
When trying to do so, on the display is viewed ACCESS ! DENIED !.
! ARM. DENIED !
LOW BATTERY
Control by Console
4-8
4.1.5

AUTOMATIC ARMING

The control panel can be armed automatically using the 4 timers. Therefore, it is
possible to schedule the arming of determined programs with a determined frequency
and at a determined time.
WARNING OF AUTOMATIC ARMING
At the time and for the period of time programmed by the installer, a warning of
imminent automatic arming is viewed on the display and the program leds on the
console blink.
According to programming, the buzzers of the consoles are activated, too.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
the exit time is to follow. The programs in question are only armed on its expiry.
Once the exit time has expired, the program leds become lit and remain lit until
disarming of these programs.
If the programs selected do not contain delayed zones, the programs in question are
armed immediately on disappearance of warning of automatic arming.
ABORT OF AUTOMATIC ARMING
Automatic arming can be aborted in the following way:
>
Enter the master code
>
Select the timer menu
>
Select the timer to be blocked
4.1.6
ARMING DURING THE ACCESS PERIODS
It is possible to define up to 2 access periods of the codes. As a consequence, the
codes are enabled for arming and disarming during the access periods associated by
the installer or the holder of the master code only.
4.1.7
ARMING DENIED
In the presence of trouble/general alarm arming is not permitted with:
Code (master or standard user) unless it is enabled for the bypass of general
alarms
Quick arming command
Key zone
On the attempt at doing so, on the display is viewed ! ARM. DENIED ! followed by
the kind of alarm.
Remove the reason of alarm or use a code enabled for the bypass of general alarms.
User Manual - TP4-20