Disarming - Technoalarm TP4-20 User Manual

4 to 20 zones control panel
Table of Contents

Advertisement

- ACCESS -
Master
Disarm.
Program x
WARNING
To abort disarming of the programs selected, press the CL-EX key (LCD020 and LCD012). The
process is aborted and the programs previously armed remain such.
- ACCESS -
User 01
TP4-20 - User Manual
4.2

DISARMING

The control panel can be disarmed through the programs (1 to 4) in one of the
following ways:
with master code or standard user code enabled for the program in question
with quick disarming command
with contact connected to a key zone
automatically by timer
4.2.1
DISARMING WITH MASTER CODE
Enter the master code (default code 12345), e.g.:
+ 12345
For the 10 seconds to come, it is possible select the programs to be armed/disarmed
(pressing the program number once the program is selected, pressing it again the
program is deselected).
On every keystroke the counter is reset.
Select the programs to be disarmed, e.g.:
+ 1 2
For 10 seconds, on the display is viewed Disarm. followed by the number/name of the
programs selected. The corresponding program LED are switched off.
It is possible to confirm the selection and abort the 10-seconds wait by pressing:
+ #
4.2.1.1
TOTAL DISARMING
After selecting the master code and during the 10 seconds destinated for the selection
of the programs ii is possible to obtain total disarming, i.e. disarming of all the
programs by pressing:
+ *
to disarm all the programs
The corresponding program LED are switched off and the control panel returns to
stand-by.
4.2.2
DISARMING WITH STANDARD USER CODE
Whereas the master code is always enabled for all the programs, the standard user
codes merely control the programs the have been enabled for by the installer or the
holder of the master code.
Enter a user code appropriately programmed, e.g. standard user code number 1:
+ 11111
For the 10 seconds to come, it is possible to select the programs to be armed/
disarmed (pressing the program number once the program is selected, pressing it
again the program is deselected).
On every keystroke the counter is reset.
Select the programs to be disarmed, e.g.:
+ 1 2
Procede as for arming with master code.
4.2.2.1
TOTAL DISARMING
After entering the user code and during the 10 seconds destinated for the selection of
the programs it is possible to obtain total disarming, i.e. disarming of all the programs
by pressing:
+ *
to disarm all the programs
The corresponding program LED are switched off and the control panel returns to
stand-by.
4.2.3
DISARMING UNDER DURESS (IF ENABLED)
In case of hold-up and/or disarming under duress it is possible to simulate disarming
of the system and release simultaneously a hold-up alarm.
For this enter the master code or a standard user code (enabled for the programs
armed) reducing the last digit by one unit, e.g. master code (default code 12345):
+ 12344
The control panel is apparently disarmed, i.e. all the program leds are switched off,
Control by Console
4-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents