- ACCESS -
User 01
Arming
Program x
- ACCESO -
Usuario 01
Arming
Program x
WARNING
Quick arming is only permitted through those consoles that have been programmed appropriately by
the installer.
It is not permitted in case of trouble/general alarm or fault (low battery, power failure etc.). At the
attempt at doing so, on the display is viewed ! ARM. DENIED ! followed by the kind of alarm.
WARNING
La conexión mediante zona llave es directa, es decir la exclusión de zonas no es posible.
No está permitida en caso de anomalía/alarma general o fallo (batería baja, falta de red etc.). Al
intentarlo, en el display se visualiza ! CON. NEGADA ! seguido del tipo de alarma activa.
TP4-20 - User Manual
4.1.2

ARMING WITH STANDARD USER CODE

Whereas the master code is always enabled for all the programs, the user codes
control merely those programs they have been enabled for by the installer or the
holder of the master code.
Enter the user code appropriately programmed, e.g. standard user code number 1:
+ 11111
For the 10 seconds to come, it is possible to select the programs to be armed/
disarmed (pressing the program number once the program is selected, pressing it
again the program is deselected).
On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+ 1 2
Procede as for arming with master code.
4.1.2.1
TOTAL ARMING
After entering the standard user code and during the 10 seconds destinated for the
selection of the programs, it is possible to obtain total arming, i.e. arming of all the
programs by pressing:
+ #
to arm all the programs
The control panel initiates the zone exclusion time.
The corresponding program leds start blinking.
4.1.3
QUICK ARMING (IF ENABLED)
It is possible to speed up the arming process by pressing the * (star) key followed by
the program number, e.g.:
+ *1
+ *2
Repeat the command for all the programs to be armed.
4.1.4
ARMING THROUGH KEY ZONE
The control panel can be armed through a contact connected to a zone programmed
by the installer as key zone.
Every time the contact is opened, all the programs that contain the key zone are
armed.
EXIT TIME
The zones defined as delayed, upon arming observe the exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
the exit time is to follow. The programs in question are only armed on its expiry.
On expiry of the exit time, the program leds become lit and remain lit until disarming of
these programs.
If the programs selected do not contain delayed zones, on expiry (or abort) of the
zone exclusion time, the programs in question are armed and the corresponding
program leds become lit immediately.
Control by Console
4-7