Arming With Master Code - Technoalarm TP4-20 User Manual

4 to 20 zones control panel
Table of Contents

Advertisement

- ACCESS -
Master
Arming
Program x
WARNING
To abort arming of the programs selected press CL-EX (LCD020 and LCD012). The process is
aborted and the control panel returns to stand-by.
TP4-20 - User Manual

4.1.1 ARMING WITH MASTER CODE

Enter the master code (default code 12345), e.g.:
+ 12345
During the 10 seconds to come, it is possible to select the programs to be armed/
disarmed (pressing the program number the first time the program is selected,
pressing it the second time it is deselected).
On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+ 1 2
Once the programs have been selected, for 10 seconds, on the display is viewed
Arming followed by the number/name of the programs selected.
The leds corresponding to the programs selected start blinking.
ZONE EXCLUSION TIME
For 10 seconds after selecting the programs, it is possible to exclude manually some
of the zones from the detection of alarms with a procedure explained lateron.
If you do not wish to exclude any zone, it is possible to confirm the selection without
awaiting the expiry of the zone exclusion time by pressing # (hash):
+ #
EXIT TIME
The zones defined as delayed, upon arming observe the exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
the exit time is to follow. The programs in question are only armed on its expiry.
On expiry of the exit time, the program leds become lit and remain lit until disarming of
LCD012
Zone-oriented
LCD console
LED06
Zone-oriented
LED console
Control by Console
4-5