WARNING
Whereas the master code is always enabled for all the programs, the user codes control merely the
programs they have been enabled for by the installer or the holder of the master code.
WARNING
If the open zones are not excluded, on expiry of the zone exclusion time (at the latest of the exit time)
the programs are armed and the open zones are activated. As a consequence, the alarm is
released.
WARNING
Outside the access periods associated, the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect.
When trying to do so, the system ignores the command.
The green LED 5 remains lit and the red program LED remain off.
After 5 seconds, the electronic keypad returns to stand-by.
Control by Keypoint and Wireless Key
5-6
5.2.1.1
ARMING WITH CODE
Enter a valid code (master or standard user code enabled for the programs to be
armed), e.g. master code (default code 12345):
+ 12345
The green LED 5 is lit.
For the 8 seconds to come it is possible to select the programs to be armed/disarmed
(pressing the program number the first time the program is selected, pressing it the
second time it is deselected). On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+ 1 3
The corresponding red program LED start blinking.
+ #
to confirm the selection and stop the counter without waiting for 8 seconds
ZONE EXCLUSION TIME
For 8 seconds after selecting the programs, it is possible to exclude manually some of
the zones from the detection of alarms with a procedure explained lateron.
If you do not wish to exclude any zone, it is possible to confirm the selection without
waiting for expiry of the zone exclusion time by pressing # (hash) again:
+ #
to confirm the selection and abort the zone exclusion time
EXIT TIME
The zones defined as delayed upon arming observe the exit time programmed by the
installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time
follows the exit time and the programs in question are only armed on expiry of the exit
time. Once the exit time has expired, the program LED become lit and remain lit until
disarming of these programs.
If the programs selected do not contain delayed zones, on expiry (or abort) of the
zone exclusion time, the programs in question are armed and the corresponding red
LED become lit immediately.
5.2.1.2
EXCLUSION OF OPEN ZONES
After selecting the programs to be armed, during the 8-seconds zone exclusion time, if
there are open zones (direct or delayed type 2), the yellow LED 7 OCG is blinking.
A zone can result open for instance in case of fault of the detector connected.
To arm the programs selected excluding the open zones press:
+ *
5.2.1.3
QUICK ARMING
Not permitted
5.2.1.4
ARMING DURING THE ACCESS PERIODS
It is possible to define 2 access periods of the codes. As a consequence, the codes
are enabled for arming and disarming during the access periods associated by the
installer or the holder of the master code only.