program in question is only armed on expiry of the exit time. Once the exit time has expired, the program LED
becomes lit and remains lit until disarming of the program.
If the program selected does not contain delayed zones, on expiry (or abort) of the zone exclusion time, the program
in question is armed and the corresponding LED becomes lit immediately.
Remove the key from the key reader.
5.1.1.2
MULTIPLE ARMING
Introduce the key into the key reader.
The LED of the first program associated to the key blinks quickly for 3 seconds. After 3 seconds, the LED
corresponding to the program selected starts blinking slowly and the 10-seconds zone exclusion time is started.
Remove the key from the key reader.
WARNING
If the key is removed and reintroduced within 3 seconds the next program is selected etc. After
selecting the third program, the key reader returns to stand-by.
ZONE EXCLUSION TIME
For 10 seconds after selecting the program, it is possible to exclude manually the open zones with a procedure
explained lateron.
If you do not wish to exclude any zone, it is however possible to select other programs in addition to the one you
have only just selected by introducing the key into the key reader again.
EXIT TIME
The zones defined as delayed upon arming observe the exit time programmed by the installer.
If the programs selected contain delayed zones, on expiry of the zone exclusion time follows the exit time and the
programs in question are only armed on expiry of the exit time. Once the exit time has expired, the program LED
become lit and remain lit until disarming of these programs.
If the programs selected do not contain delayed zones, on expiry (or abort) of the zone exclusion time, the programs
in question are armed and the corresponding leds become lit immediately.
5.1.1.3
EXCLUSION OF OPEN ZONES
After selecting the programs to be armed, during the 10-seconds zone exclusion time, if there are open (direct)
zones, the yellow OCG LED is blinking.
A zone may result open for instance in case of fault of the detector connected.
To arm the programs selected with exclusion of open zones introduce and remove the key until the program required
is selected. Leave the key in the key reader for the entire zone exclusion time.
The zones remain excluded until disarming of the program. They are activated automatically again the next time the
program is armed.
WARNING
If the open zones are not excluded, on expiry of the zone exclusion time (or at the latest of the exit
time) the programs are armed and the open zones are activated. As a consequence, the alarm is
released.
5.1.2

DISARMING

5.1.2.1
SINGLE ARMING
Introduce an electronic key enabled for the program armed into the key reader.
The program is disarmed and the corresponding LED is switched off.
Remove the key from the key reader.
5.1.2.2
MULTIPLE ARMING
DIRECT DISARMING ENABLED
Introduce a key enabled for the programs armed into the key reader.
All the programs associated are disarmed simultaneously and the corresponding LED are switched off.
Remove the key from the key reader.
DIRECT DISARMING DISABLED
Introduce a key enabled for the programs armed into the key reader and remove it until the program to be disarmed
is selected.
The program selected is disarmed and the corresponding led is switched off.
Remove the key from the key reader.
WARNING
The electronic key introduced will effect disarming exclusively of the programs it is enabled for.
Possible other programs armed are not affected.
TP4-20 - User Manual
Control by Keypoint and Wireless Key
5-3