5.1.1.1
SINGLE ARMING
Introduce the electronic key into the key reader.
The LED of the first program associated to the key blinks quickly for 3 seconds. After 3 seconds, the LED
corresponding to the program selected starts blinking slowly and the 10-seconds zone exclusion time is started.
Remove the key from the key reader.
WARNING
If the key is removed and reintroduced within 3 seconds, the next program is selected etc. After
selecting the third program, the key reader returns to stand-by.
ZONE EXCLUSION TIME
For 10 seconds after selecting the program, it is possible to exclude manually the open zones with a procedure
explained lateron.
If you do not wish to exclude any zone, it is however possible to select another program deselecting the one you
have only just selected by introducing the key into the key reader again.
WARNING
On arming of a program in the presence of open zones, the alarm devices programmed (sirens/logic
outputs/telephone channels) are activated unless the open zones are exluded with a procedure
explained lateron.
EXIT TIME
The zones defined as delayed upon arming observe the exit time programmed by the installer.
If the program selected contains delayed zones, on expiry of the zone exclusion time follows the exit time and the
Control by Keypoint and Wireless Key
5-2
User Manual - TP4-20