2.2

CONSOLE LCD012

This kind of console permits program status signaling and zone status signaling for the first 12 zones of the control
panel through coloured leds and an LCD display.
TP4-20 - User Manual
PROGRAM STATUS LED (1...4)
LED off
1
LED blinking quickly
LED blinking slowly
LED on
KEYPAD
2
LABELS FOR ZONE DESCRIPTION
3
FALSE CODE ALARM LED
LED off
4
LED blinking
LED on
GENERAL ALARM LED
LED off
5
LED blinking
LED on
TAMPER ALARM LED
LED off
6
LED blinking
LED on
BATTERY LED
LED off
7
LED blinking
LED on
ZONE ALARM LED (1...12)
LED off
8
LED blinking
LED on
DISPLAY Indicates date/time or active parameter
9
RECLOSABLE PROTECTION FLAP
10
2.2.1
PROGRAM STATUS LED
(YELLOW)
The yellow program status led signals program status (1 to 4):
Led blinking quickly = program during arming phase
The arming phase is the lapse of time from entering the code
until actual arming of the control panel. It depends on the
exit time programed (if the system contains delayed zones).
Led blinking slowly = program partset
Led on = program armed
The led remains lit until disarming of the program.
Led off = program disarmed
The events, arming, disarming and bypass, are stored in the
event buffer of the control panel with indication of date and time.
2.2.2
ZONE ALARM LED
(RED)
Zone alarm is only released if the program the zone is included in
is armed. The red zone alarm led signals open zones.
CONTROL PANEL ARMED
Led blinking = alarm active
The led starts blinking upon detection of an alarm on one of
the zones included in the program and continues blinking
during the entire alarm time. Depending on programming, the
indoor and/or outdoor sirens are activated, too.
Once the alarm has stopped, the led is switched off.
CONTROL PANEL IN STAND-BY
Led on = alarm stored (alarm memory)
The led becomes lit on disarming of the control panel, and is
lit until the program is armed again.
Led off = no alarm
Program in stand-by
Program in arming phase
Program partset
Program armed
No alarm
False code alarm active
Alarm stored (alarm memory)
No alarm
Alarm active
Alarm stored (alarm memory)
No alarm
Alarm active
Alarm stored (alarm memory)
No alarm
Low battery voltage
Alarm stored (alarm memory)
No alarm
Alarm active
Alarm stored (alarm memory)
Signaling