Arming
Deact. bypass
WARNING
The alarm is released if 32 keys are pressed without entering a valid code. In case of false code
alarm, the buzzers of all the consoles connected are activated for 30 seconds and the console that
has released the alarm is disabled for 2 minutes. To stop the alarm, enter a valid code (master or
standard user) on any other console.
Abort telephone?
* NO
# YES
WARNING
The abort of the telephone calls is only permitted with master code or one of the first 9 standard user
codes. The abort command stops all the active alarm calls cycles as well as those waiting.
The abort of the telephone calls is not permitted in case of hold-up alarm. In this case, the cycle
continues uninterrupted.
Control by Console
4-12
4.3.6
DEACTIVATION OF BYPASS ON EXPIRY OF THE
MAXIMUM BYPASS TIME
If a maximum bypass time has been programmed by the installer, on expiry of this
time, the bypass is automatically deactivated.
WARNING OF IMMINENT ARMING
For a period of time programmed by the installer before expiry of the maximum
bypass time, on the display is viewed a warning of imminent arming due to expiry of
maximum bypass time and the program leds on the console become lit.
According to programming, the buzzers of the consoles are activated, too.
4.4
RELEASE OF PANIC ALARM
In case of danger the user can release a panic alarm by pressing the keys arrow up
and arrow down (wy) on the console simultaneously even if the control panel is in
stand-by.
If programmed accordingly, the control panel activates a call for panic alarm.
4.5
RELEASE OF FALSE CODE ALARM
4.6
VIEWING OF ZONE STATUS
To check zone status if the control panel is in stand-by press # (hash):
+ #
On the display (LCD020 and LCD012) the open zones are viewed in sequence with
an interval of approximately 2 seconds between one and the next (see paragraph
4.1). After scanning of the zones the control panel returns to stand-by.
4.7
ABORT OF TELEPHONE CALLS
4.7.1
MANUAL ABORT OF THE TELEPHONE CALLS
During a telephone call, to stop manually the active alarm call cycle and those waiting
enter a code enabled for the manual abort of the telephone calls (master or one of the
first 9 standard user codes) followed by the key CL-EX, e.g. master code (default
code 12345):
+ 12345 CL-EX
Commands available
+ #
to block the telephone calls
+ *
to abort the block of the telephone calls and quit