5.2

CONTROL BY ELECTRONIC KEYPAD TP SDN

The electronic keypad permits the control of the 4 programs with code. It does not accept the installer code and does
not permit programming.
5.2.1
ARMING
The control panel can be armed through the programs (1 to 4). The electronic keypad permits arming/disarming and
bypass of maximum 4 programs with master code or standard user code enabled for the program in question.
The programs group the zones (1 to 20) that are activated, i.e. are enabled for the detection of alarms,
simultaneously upon arming of the program. The programs can be armed one at a time (single arming) or
simultaneously (multiple arming).
The electronic keypad permits arming with exclusion of open zones.
Common zones (if multiple arming is enabled only)
If a zone is included in several programs and is defined as common zone, it is enabled for the detection of alarms
only when all the programs it is included in are armed.
Example: if a system is used by two appartments that share the same entrance zone, the owners of the appartments
can arm the proper part of the system independently through the program/s associated to it and with the proper user
codes. The common zone (entrance), however, is activated only if the programs of both appartments it is included in
are armed simultaneously.
TP4-20 - User Manual
CHECK SYSTEM STATUS
Prior to arming of the control panel always check system status with the help of the
LED on the keypad:
LED 7 OCG (YELLOW)
blinking
on
LED 6 GENERAL ALARM (RED)
blinking
on
CHECK ZONE STATUS
Open zones/active zone alarms are not signaled unless you try to arm the control
panel. In the arming phase the yellow LED 7 OCG signals zone status:
LED blinking
LED off
= control panel armed and one of the programs
associated in alarm
= alarm stored (alarm memory)
= trouble or general alarm active (e.g. low battery,
power failure, tamper)
= alarm stored (alarm memory)
= open zones
= zones ok
Control by Keypoint and Wireless Key