Arming - Technoalarm TP4-20 User Manual

4 to 20 zones control panel
Table of Contents

Advertisement

Fri
30 JAN 04
Work.
11 : 15
OPEN ZONES
None
OPEN ZONES
Zone 2
WARNING
On arming of the program in presence of open zones, the alarm devices programmed (sirens/logic
outputs/telephone channels) are activated unless the open zones are excluded with a procedure
explained lateron.
Control by Console
4-4
4.1

ARMING

The control panel can be armed through the programs (1 to 4) in one of the following
ways:
with master code or standard user code enabled for the program in question
with quick arming command
with contact connected to a key zone
automatically by timer
The programs group the zones (1 to 20) to be activated, i.e. enabled for the detection
of alarms, simultaneously upon arming of the program. The programs can be armed
one at a time (single arming) or simultaneously (multiple arming).
Common zones (if multiple arming is enabled only)
If a zone is included in several programs and is defined common zone, it is enabled
for the detection of alarms only when all the programs it is included in are armed.
Example: if a system is used by two appartments that share the same entrance zone,
the owners of the appartments can arm the proper part of the system independently
through the program/s associated to it and with the proper user codes. The common
zone (entrance), however, is activated only if the programs of both appartments it is
included in are armed simultaneously.
The system distinguishes two tipes of consoles:
LCD020
LCDconsole program-oriented
LCD012
LCD console zone-oriented
LED06
LED console zone-oriented
Todas las tres consolas permiten la conexión/desconexión y la parcialización de los 4
programas. Además, permiten la conexión con exclusión de las zonas abiertas.
CHECK SYSTEM STATUS
Prior to arming of the control panel, when the control panel is in stand-by, always
check the status of the zones (detectors) pressing # (hash):
+ # (YES)
On the display (LCD020 and LCD012) are viewed the zones that result open in
sequence with an interval of approx. 2 seconds between one another. After scanning
of the zones the control panel returns to stand-by.
VIEWING OF SYSTEM STATUS
LCD020
Program-oriented
LCD console
User Manual - TP4-20