Bypass - Technoalarm TP4-20 User Manual

4 to 20 zones control panel
Table of Contents

Advertisement

Act. bypass
Program 1
WARNING
The zones excluded are those associated to the bypass function and included in the program/s
selected.
ATENCION
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect.
When trying to do so, on the display is viewed ACCESS ! DENIED !.
Deact. bypass
Program 1
Arming
Automatic
TP4-20 - User Manual
4.3

BYPASS

When the control panel is armed, it is possible to deactivate temporaneously part of
the system. Upon activation of the bypass, the zones enabled for bypass and
included in the program/s armed and partset are deactivated. The other zones are not
affected.
The exclusion of zones persists until deactivation of bypass or disarming of the
programs they are included in.
4.3.1
ACTIVATION OF BYPASS WITH CODE
Enter a code enabled for bypass (master or standard user code enabled for the
programs armed) followed by the number of the program to be partset, e.g.:
+ 66778
+ 1
On the display is viewed Act. bypass followed by the program partset.
For the time the bypass is active the corresponding program led is blinking.
4.3.2
AUTOMATIC ACTIVATION OF BYPASS
The control panel can be partset automatically using the 4 timers. Therefore, it is
possible to schedule the activation of bypass with a determined frequency and at a
determined time acting on determined programs.
At the time programmed the timer partsets the programs associated.
4.3.3
ACTIVATION OF BYPASS DURING THE ACCESS
PERIODS
It is possible define up to 2 access periods of the codes. As a consequence, the
codes are enabled for bypass during the access periods associated by the installer or
holder of the master code only.
4.3.4
DEACTIVATION OF BYPASS WITH CODE
Enter a code enabled for bypass (master or standard user enabled for the programs
armed) followed by the number of the program to be reactivated in its integrity, e.g.:
+ 66778
+ 1
On the display is viewed Deact. bypass followed by the program to be reactivated in
its integrity.
The led of the program previously partset becomes lit.
4.3.5
AUTOMATIC DEACTIVATION OF BYPASS
The bypass can be deactivated automatically using the 4 timers. Therefore, it is
possible to schedule the deactivation of the bypass with a determined frequency and
at a determined time acting on determined programs.
At the time programmed the timer deactivates the bypass and reactivates the
programs associated in their integrity.
WARNING OF IMMINENT AUTOMATIC ARMING
At the time and for the period of time programmed by the installer on the display is
viewed a warning of imminent automatic arming and blink the program leds on the
console.
According to programming, the buzzers of the consoles are activated, too.
Control by Console
4-11