LOW BATTERY
Control panel
Sat
01 - - - 00
Work.
00 : 01
! TROUBLE !
CUT TEL. LINE
! TROUBLE !
GSM FAULT
TP4-20 - User Manual
Both events, low battery and battery restore, are stored in the
event buffer with indication of date and time. In case of low
battery of a wireless devíce, to identify the device that has
released the alarm, consult the event buffer of the control panel.
SIGNALING ON DISPLAY
In case of low battery alarm, beside led signaling, on the display
is viewed the module that has released the alarm.
WARNING
If in presence of power failure alarm, battery voltage drops below 9V, the battery is
automatically disconnected in order to avoid its definite and irrevocable discharge. In
this case the clock is lost, whereas system status and the event buffer are
maintained.
Upon battery restore, the clock is shown as on opposite illustration with unvalid
month field. It is necessary to program the date and time, otherwise all the
scheduled functions (automatic arming, test call, access periods of the codes/keys
etc.) remain deactivated.
2.2.5
The red general alarm led signals trouble and general alarm.
These alarms are direct and are detected always, even if the
control panel is in stand-by, in case of:
The led produces the following signaling:
GSM trouble alarm is released after approx. 10 seconds from
its detection.
The general alarms are stored in the event buffer of the control
panel with indication of date and time. Antimasking, supervision,
cut telephone line and GSM trouble alarm is stored with
indication of date and time of beginning and end of alarm.
SIGNALING ON DISPLAY
In case of cut telephone line alarm or GSM trouble, beside led
signaling, on the display is viewed the kind of alarm.
2.2.6
The red key led signals false code or false key alarm:
The led produces the following signaling:
False code or false key alarms are stored in the event buffer of
the control panel with indication of date en time.
Led on = alarm stored (alarm memory)
The led becomes lit upon battery restore and remains lit on
disarming of the control panel (if it is armed), and in any
case until it is armed again.
GENERAL ALARM LED
(RED)
Antimasking alarm of the wireless receiver (significant
interferences)
Supervision alarm of a wireless device (the device fails to
carry out the test transmission towards the control panel for
more than the time programmed)
Cut telephone line (missing of telephone line voltage for
approx. 1 minute)
Trouble GSM module (communication between the module
and the control panel interrupted for approx. 10 seconds)
Led blinking = alarm active
Led on = alarm stored (alarm memory)
KEY LED
(RED)
False key (attempt at arming with unknown key)
False code (pressing of 32 keys without entering a valid
code)
Led blinking = alarm active
The led blinks for 2 minutes and the buzzers of the consoles
are activated at intermittence for 2 minutes. In addition, the
keypad of the console that has released the alarm is
inhibited for 2 minutes. The keypad block can be undone by
entering a valid code on another console/electronic keypad
of the system.
Led on = alarm stored (alarm memory)