Chapter 10 Automated tests

Associating test records with test results

Associating test records with test results

156
To run a wideband autotest
1
Connect the Tip (A), Ring (B), and Ground (Earth) leads
to the line under test.
2
Access the Copper Scripts menu (see
3
Press the 5 key to select Copper Expert with FED.
4
Select a configuration:
If you want to...
run the configuration as is
specify a different config-
uration
5
Start the test by selecting Run Test.
As the test runs, the status and results of the test are
displayed.
After running all tests, the status of the pair is displayed along
with advice on how to proceed.
A test record describes general information about a test. A
test record can include work order number, technician name
and ID, circuit ID, and location. You can associate a test
record with up to two test result files.
For information about creating, modifying and deleting test
records, see the HST-3000 Base Unit User's Guide.
To associate a test record with test results
1
After running the Auto Test, press the OK key to
Continue.
HST-3000 Copper Testing User's Guide
page
do this...
press the 1 key
press the 2 key to specify the
termination
press the 3 key to specify the
technology
146).