Performing Two-Pair Wideband Measurements - JDS Uniphase HST-3000 User Manual

Copper testing
Hide thumbs Also See for HST-3000:
Table of Contents

Advertisement

Chapter 8 Wideband testing
Performing WB2 measurements
Performing two-
pair wideband
measurements
120
6
Optional. To change the amplitude of the signal, press
the Actions soft key, and then select Amplitude. Type
the new amplitude in the dialog box, and then press the
OK key.
7
Optional. Change the frequency by using the left and
right arrows.
NOTE:
The arrow keys are only available if transmitting a standard
tone and will move among only those frequencies.
8
Optional. To change termination, do the following:
a Press the Actions soft key.
b Select Termination.
c Select a termination.
To select...
100 ohm
135 ohm
9
Press the Results soft key to save or clear the results.
10 Press the Stop soft key.
Transmitting tones is complete.
Some provisioning situations involve two pairs; one example
is HDSL-4, which requires a two pairs. You can use the
HST-3000 to test both pairs simultaneously.
To measure loss on both pairs
1
Connect the Tip (A), Ring (B), T1 (A1), R1 (B1), and
Ground (E) leads to the line under test, as described in
"Connecting to the line" on page 113
connections for two lines).
2
Press the Actions soft key, and then select Simulta-
neous Tx/Rx Tones.
HST-3000 Copper Testing User's Guide
Press...
the 1 key
the 2 key
(a total of four