SC-S30600 Series
4.10 CR Related Adjustments
4.10.1 CR Belt Tension Check
REQUIRED TOOLS
Sonic tensimeter U-507
Any tools to flip the belt
STANDARD VALUE
48 ± 2 N
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Remove the following parts in advance.
Left Cover
(P. 98)
2.
When any paper is loaded, remove it.
3.
Turn the printer ON.
4.
Start the Service Program and select
5.
Click [Run].
The CR Unit moves left and right three times, and then moves to the center.
ADJUSTMENT
CR Belt Tension
Check.
CR Related Adjustments
Figure 4-14. [CR Belt Tension Check] Screen
6.
Input the following values to the tensimeter.
MASS:
1.0 g/m
WIDTH:
10.0 mm/R
SPAN:
1170 mm
7.
Bring the microphone of the tensimeter closer to the position shown in
4-15.
C H E C K
Bring the microphone within 5 mm from the belt but do not let it
P O I N T
touch the belt.