3.4.5.14 Pump Cap Unit
When replacing/removing this part, refer to
A D J U S T M E N T
R E Q U I R E D
Items and the Order by Repaired Part" (p200)
perform the specified operations including required adjustment.
1.
Unlock the CR Unit.
(p82)
2.
Remove the Media Loading Lever.
3.
Remove the Panel Unit.
(p86)
4.
Remove the Right Upper Cover.
5.
Remove the Right Cover.
(p92)
6.
Move the CR Unit to a position over the platen.
7.
Remove the screw, and remove the cable cover.
A) Silver M4x8 S-tite screw with built-in washer: 1 pcs
When installing the cable cover, be careful not to let the cable get
caught between the cover and frame.
DISASSEMBLY & ASSEMBLY
"4.1.2 Adjustment
and make sure to
(p158)
(p88)
Disassembly and Assembly Procedure
A
Figure 3-91. Removing the Cable Cover
8.
Open the clamp.
9.
Disconnect the cable from the three relay connectors (No.36, No.37, and No.79).
Clamp
Figure 3-92. Disconnecting from the Relay Connectors
Revision B
Cable Cover
aa
No.36
No.37
No.79