SC-S30600 Series
3.4.3.13 R Maintenance Cover Sensor
1.
Remove the Media Loading Lever.
2.
Remove the Panel Unit.
(p86)
3.
Remove the Right Upper Cover.
4.
Remove the Board Box Cover.
(p101)
5.
Disconnect the cable from the connector (CN272) on the Main Board.
6.
Release the cable from the five clamps.
7.
Release the cable from the three FFC clamps.
DISASSEMBLY & ASSEMBLY
(p158)
(p88)
Disassembly and Assembly Procedure
- Right upper side -
FFC Clamp
R Maintenance Cover Sensor Cable
Clamp
- Right rear side -
CN272
Figure 3-38. Releasing the Cable
Revision B
FFC Clamps
Clamps
Clamp
Clamp
Main Board
102
Confidential