SC-S30600 Series
4.13 Media Feed Related Checks and Adjustments
4.13.1 PF Belt Tension Check
REQUIRED TOOLS
Sonic tensimeter U-507
Any tools to flip the timing belt
STANDARD VALUE
11 ± 4 N
EXECUTION MODE
Normal Mode
PROCEDURE
1.
Remove the following part in advance.
Left Cover
(P. 98)
2.
Loosen the two screws that secure the PF Motor mounting plate.
3.
Move the mounting plate back and forth three times to soften the PF timing belt.
4.
Tighten the two screws to secure the mounting plate.
ADJUSTMENT
Tension spring
Fixing screws
PF Motor mounting plate
Media Feed Related Checks and Adjustments
Measuring microphone
Figure 4-51. PF Belt Tension Check
Revision B