8.
Press [MEASURE] on the tensimeter and flip the belt with tweezers or a similar
tool.
Be sure to measure the tension of the belt on the upper side. If
C A U T I O N
you measure the tension of the belt on the lower side, the
measuring value may be inaccurate.
Flip the belt as weak as the tensimeter can measure it.
Be careful not to let the microphone touch the belt when
flipping the belt.
9.
Measure the belt tension for three times, and check if the average is within the
standards.
Within the standards: Go to
Step 10
Out of the standards: Go to
Step 12
10. Click [Finish].
11. Turn the printer OFF to finish the adjustment.